{"id":284,"date":"2018-08-25T22:04:23","date_gmt":"2018-08-25T22:04:23","guid":{"rendered":"http:\/\/powerupgs.com\/site\/?page_id=284"},"modified":"2018-08-25T22:04:23","modified_gmt":"2018-08-25T22:04:23","slug":"d85-unitized","status":"publish","type":"page","link":"https:\/\/powerupgs.com\/site\/forney-corporation\/flame-detector\/d85-unitized\/","title":{"rendered":"D85 Unitized"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;285,286&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h4 class=\"custom-prod-title\">Product:\u00a0D85 Unitized<\/h4>\n<p>The Forney D85 series is a microprocessor based flame detector utilizing a solid state flame detection sensor. The D85 incorporates an internal flame relay with automatically set ON\/OFF thresholds and advanced programming features for fine tuning.<\/p>\n<p>Forney\u2019s D85 series flame detectors provide unparalleled ease of installation and operation, with fully automatic flame characterization and optimum gain detection.<\/p>\n<p><a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/12\/FEX1_Notice.pdf\" target=\"_blank\" rel=\"noopener\">FEX Product Advisory<\/a>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs][vc_tta_section title=&#8221;Product Overview&#8221; tab_id=&#8221;1535228058413-12a31845-683a5426-2a926f74-14604c79-73ab&#8221;][vc_column_text]The Forney D85 series is a microprocessor based flame detector utilizing a solid state flame detection sensor. The D85 incorporates an internal flame relay with automatically set ON\/OFF thresholds and advanced programming features for fi ne tuning.<\/p>\n<p>Forney\u2019s D85 detects the modulation of the target flame\u2019s amplitude (flame \u201cflicker\u201d) over a wide frequency. During the detector setup the amplitudes of the target flame are automatically stored in the flame detector along with optimum ON\/OFF criteria. The appropriate sensor gain is also automatically selected and stored. Forney D85 detectors incorporate full self-diagnostic and electronic self-checking.<\/p>\n<p>Forney D85 flame detectors are powered by 24Vdc with standard analog 4-20mA flame signal strength output. Electrical connection is via an 8-pin electrical quick-disconnect (QD) fitting for standard models. CEX models utilize internal terminal blocks.<\/p>\n<p>Forney D85 flame detectors are available in multiple models based on spectral range (UV or IR), hazardous area classifi cations and agency approvals.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Technical Data&#8221; tab_id=&#8221;1535228058480-927f5ae5-e2315426-2a926f74-14604c79-73ab&#8221;][vc_column_text]<\/p>\n<h4>Part Number for D85 Detector Heads<\/h4>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-519\" src=\"http:\/\/forneycorp.com\/wp-content\/uploads\/2014\/01\/d85-series-part-number.jpg\" sizes=\"auto, (max-width: 381px) 100vw, 381px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/d85-series-part-number.jpg 381w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/d85-series-part-number-300x51.jpg 300w\" alt=\"d85-series-part-number\" width=\"381\" height=\"66\" \/><br \/>\nSample Part Number: D85 UV FM QD = D85 Model with UV sensor, Front Mount and Quick Disconnect Connection.<\/p>\n<h4>Mechanical Speci\ufb01cations:<\/h4>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\" width=\"17%\">Housing Material:<\/td>\n<td align=\"left\" valign=\"top\" width=\"44%\">Standard Models: Engineered material \u2013 GE Valox<\/td>\n<td align=\"left\" valign=\"top\" width=\"39%\">CEX Models: Aluminum, painted \ufb01 nish<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td align=\"left\" valign=\"top\">Standard Models: NEMA 4X, IP66 \/ Class I Div II<\/td>\n<td align=\"left\" valign=\"top\">CEX Models: Ex II 2 G\/D, ATEX certi\ufb01ed<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Detector Weight:<\/td>\n<td align=\"left\" valign=\"top\">Standard Models: 3.30 lbs (1.5kg)<\/td>\n<td align=\"left\" valign=\"top\">CEX Models: 9.5 lbs (4.3kg)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Cooling \/ Purge Air<\/td>\n<td align=\"left\" valign=\"top\">Source: Clean, dry, cool<\/td>\n<td align=\"left\" valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Requirements:<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">Volume: 10 SCFM (113 l\/min) at 3\/8\u201d threaded mounting \ufb02 ange, or 1 inch \u201cY\u201d \ufb01 tting, mounted on scanner sight pipe. Temperature near the upper limit of the operating range and\/or dirty fuels may require up to 15 SCFM (425 l\/min).<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">Pressure: Adequate to overcome furnace or windbox pressure<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Environmental:<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">-40\u00b0 F to + 150\u00b0F (-40\u00b0C to +65\u00b0C), 0-95% relative humidity, non-condensing<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Mounting<br \/>\nOrdered Separately):<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">Standard Models: P\/N 35-318-1, Standard, non-metallic, 1\u201d NPT female pipe mount \ufb02 ange with 3\/8\u201d NPT female cooling air connection<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">P\/N 35-318-2, Standard, non-metallic, 1\u201d BSP female pipe mount \ufb02 ange with 3\/8\u201d BSP female cooling air connection<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">P\/N 129-182-1, Optional, aluminum 1\u201d NPT kit for standard models with 3\/8\u201d NPT female cooling air connection<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">P\/N 129-182-2, Optional, aluminum 1\u201d BSP kit for standard models with 3\/8\u201d BSP female cooling air connection<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">CEX Models: P\/N 129-168-1, 1\u201d NPT female pipe mount \ufb02 ange with 3\/8\u201d NPT female cooling air connection<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\"><\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">P\/N 129-168-2, 1\u201d BSP female pipe mount \ufb02 ange with 3\/8\u201d BSP female cooling air connection<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Optical:<\/td>\n<td colspan=\"2\" align=\"left\" valign=\"top\">UV Models: 295 to 340 nanometers (K3 option 310-500 nanometers); IR Models: 830 to 1100 nanometers<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Electrical Speci\ufb01cations:<\/h4>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\" width=\"17%\">Input Power:<\/td>\n<td align=\"left\" valign=\"top\" width=\"33%\">24 Vdc, +20%, -15% supply current 200mA<\/td>\n<td align=\"left\" valign=\"top\" width=\"14%\">Status Indication:<\/td>\n<td align=\"left\" valign=\"top\" width=\"36%\">Multiple LED indication for \ufb02ame signal strength,<br \/>\n\ufb02ame relay, ready, target, background select and fault<br \/>\ncodes<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Electrical Connection:<\/td>\n<td align=\"left\" valign=\"top\">Standard Models: 8-pin quick disconnect<br \/>\nCEX Models: internal terminal blocks<\/td>\n<td rowspan=\"4\" align=\"left\" valign=\"top\">Cable Speci\ufb01cation:<\/td>\n<td rowspan=\"4\" align=\"left\" valign=\"top\">Quick Connect P\/N 401119-xx, Bulk Cable<br \/>\nP\/N 401119-00 Multi-core, 8 (color coded) Eight<br \/>\n#18 AWG with foil wrap and overall braided shield.<br \/>\nPLTC-ER rating.<br \/>\nTemperature Rating: -40\u00b0F to 221\u00b0F (-40\u00b0C to 105\u00b0C)<br \/>\nCable Jacket: PVC (\ufb02 ame-retardant, low smoke, zero<br \/>\nhalogen)<br \/>\nNominal O.D. 0.44\u201d (11.2 mm); Maximum O.D.<br \/>\n0.48\u201d (12.2 mm)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Relay Output:<\/td>\n<td align=\"left\" valign=\"top\">FLAME RELAY, SPST (N.O.)<br \/>\nFAULT RELAY, SPST (N.C.)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Contact Rating:<\/td>\n<td align=\"left\" valign=\"top\">Minimum: 10mA @ 5 Vdc<br \/>\nMaximum: 2A@30 Vdc, 2A@230 Vac Resistive load<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Analog Output:<\/td>\n<td align=\"left\" valign=\"top\">Optically isolated 4-20mA dc current referenced to 24<br \/>\nVdc common, maximum connected load: 750 Ohms.<br \/>\nForney recommends the 60-2685-X 24 Vdc power<br \/>\nsupply for best performance and for a SELV rating of<br \/>\nthe 4-20mA analog output leads.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Drawings&#8221; tab_id=&#8221;1535228099870-cf2e50d8-09be5426-2a926f74-14604c79-73ab&#8221;][vc_column_text]<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-521\" src=\"http:\/\/forneycorp.com\/wp-content\/uploads\/2014\/01\/d85-drawing.jpg\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/d85-drawing.jpg 512w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/d85-drawing-300x232.jpg 300w\" alt=\"d85-drawing\" width=\"512\" height=\"397\" \/>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Featured &amp; Benefits&#8221; tab_id=&#8221;1535228100664-93557475-11d55426-2a926f74-14604c79-73ab&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Rapid installation and configuration with quick disconnects and fully automated tuning.<\/li>\n<li>Advanced, programmable settings for more demanding applications<\/li>\n<li>Expanded diagnostic analysis for superior flame characterization and troubleshooting.<\/li>\n<li>Multiple UV and IR fl ame detection options support a wide range of combustion processes including: industrial burners, duct burners, refinery applications, low NOx burners, waste fuel units and incinerators.<\/li>\n<li>Integrated sensor and electronics eliminates need for external amplifiers.<\/li>\n<li>Standard NEMA 4X, IP66 housing for Class I, Div 2 environments<\/li>\n<li>Optional CEX models for ATEX Ex II 2 G\/D environments<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Resources&#8221; tab_id=&#8221;1535228101519-87562f93-8d975426-2a926f74-14604c79-73ab&#8221;][vc_column_text]<a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/03\/D85_rev02-2015.pdf\">D85 Flame Detector Technical Bulletin Publication<\/a><br \/>\n#404005-26[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;285,286&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Product:\u00a0D85 Unitized The Forney D85 series is a microprocessor based flame detector utilizing a solid state flame detection<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":256,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-284","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/284","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/comments?post=284"}],"version-history":[{"count":1,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/284\/revisions"}],"predecessor-version":[{"id":287,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/284\/revisions\/287"}],"up":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/256"}],"wp:attachment":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/media?parent=284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}