{"id":266,"date":"2018-08-25T21:54:55","date_gmt":"2018-08-25T21:54:55","guid":{"rendered":"http:\/\/powerupgs.com\/site\/?page_id=266"},"modified":"2018-08-25T21:54:55","modified_gmt":"2018-08-25T21:54:55","slug":"idd-9000-flame-detector-amplifier","status":"publish","type":"page","link":"https:\/\/powerupgs.com\/site\/forney-corporation\/flame-detector\/idd-9000-flame-detector-amplifier\/","title":{"rendered":"IDD 9000 Flame Detector Amplifier"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;267,268,269&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h4 class=\"custom-prod-title\">Product:\u00a0IDD 9000 Flame Detector Amplifier<\/h4>\n<p>The IDD 9000 Flame Detector Amplifier provides enhanced discrimination and tuning for NFPA compliant systems and offers a single retrofit solution for multiple discrete legacy amplifiers.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs][vc_tta_section title=&#8221;Product Overview&#8221; tab_id=&#8221;1535228058413-12a31845-683a5426-2a926f74-146015e6-4a3f&#8221;][vc_column_text]Reliable flame detection and burner-to-burner discrimination in multi-burner boilers is significantly more challenging with the NFPA 85 requirement to prove \u201cflame not detected\u201d prior to burner start-up. This NFPA requirement along with difficult discrimination challenges, such as low NOx burners and opposed fired boilers, are demanding more powerful signal analysis and tuning capability from flame detection systems. The IDD 9000 employs a Digital Signal Processor (DSP) based flame signal processing method to offer advanced tuning capabilities necessary for a NFPA compliant system.<\/p>\n<p>The IDD 9000 Flame Amplifier is designed for easy upgrade of existing Forney flame amplifiers with most installations simply requiring a flame amplifier replacement and reconnection of existing wires to improve flame detection and discrimination. The IDD 9000 is available in panel or rack mount; single or dual channel configurations. The dual channel configurations use two fully independent channels to support two flame detectors simultaneously.<\/p>\n<ul>Compatibility<\/p>\n<li>Amplifier Upgrades \u2013 The IDD 9000 can replace most Forney flame amplifiers, panel or rack mount, in any application with complete compatibility.<\/li>\n<li>Flame Detector \u2013 Works with all versions of Forney\u2019s IDD and UV-4 detectors.<\/li>\n<li>Analog Output \u2013 Flame intensity output is available in either 0-10 VDC or 4-20 mA.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Technical Data&#8221; tab_id=&#8221;1535228058480-927f5ae5-e2315426-2a926f74-146015e6-4a3f&#8221;][vc_column_text]<\/p>\n<h4>Products and Accessories:<\/h4>\n<div class=\"tech-data\">Dual Channel Panel Mount (PM) IDD 9000 Amplifier Part #408100-00<br \/>\nSingle Channel Panel Mount (PM) IDD 9000 Amplifier Part #408100-50<br \/>\nRack Mount (RM) IDD 9000 Amplifier \u2013 dual channel Part #408120-01<br \/>\nAmplifier Tuning Kit Part #408103-01<br \/>\nTermiflex \/ SMARTDisplay\u00aeterminal with 9-pin connector* Part #408106-01<br \/>\nCable 40\u2019(for IDD) Part #399854-04<br \/>\nCable 40\u2019(for UV-4) Part #399855-04<\/p>\n<h4>Compatible Flame Detectors:<\/h4>\n<ul>\n<li>IDD-II, Filtered, Infrared Detector Part #38321-21<\/li>\n<li>IDD-IIU, Unfiltered, Infrared Detector Part #38321-22<\/li>\n<li>IDD-IIL, Infrared Detector for Lignite Part #38321-23<\/li>\n<li>UV-4, UV Tube Detector Part #379189-02<\/li>\n<\/ul>\n<\/div>\n<p>*If using an older Termiflex \/ SMARTDisplay \u00ae terminal with a 25-pin connection, a DB25-pin to DB9-pin adapter is required (Forney Part #408107-01)<\/p>\n<h4>IDD 9000 Specifications:<\/h4>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"26%\"><\/td>\n<td align=\"center\" valign=\"top\" width=\"37%\">Panel Mount:<\/td>\n<td align=\"center\" valign=\"top\" width=\"37%\">Rack Mount:<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Dimensions:<\/td>\n<td valign=\"top\">10 1\/2\u201d x 7 7\/8\u201d x 3 7\/8\u201d (26.6 cm x 20 cm x 9.8 cm)<\/td>\n<td valign=\"top\">6.5 x 14 x 1.75 inches (155.6 x 355.6 x 44.5 mm)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Weight:<\/td>\n<td valign=\"top\">5 lbs. 3 oz.<\/td>\n<td valign=\"top\">1 lb 7 oz.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Temperature:<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">32\u00b0 to 140\u00b0F (0\u00b0 to 60\u00b0C)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Humidity:<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">5% to 95% relative humidity, non-condensing<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power Requirements:<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">120\/240 VAC, 50\/60 Hz @ 12 VA<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Output Relay Ratings (SPDT):<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">3 A at 125 VAC, 250 VAC &amp; 30 VDC<br \/>\n3 relays are available for each channel (Lamp, Main Flame &amp; Alarm).<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flame Strength:<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">4-20 mA or 0-10 VDC (sourcing)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flame Failure Response Time (FFRT):<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">2.0, 3.0 or 3.8 seconds<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Flame Pickup Time:<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">less than 2 seconds<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Nonvolatile RAM:<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">8 complete operating profiles<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Approvals:<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">Factory Mutual (FM)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Drawings&#8221; tab_id=&#8221;1535228099870-cf2e50d8-09be5426-2a926f74-146015e6-4a3f&#8221;][vc_column_text]<\/p>\n<h4>Panel Mount IDD 9000<\/h4>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-473\" src=\"http:\/\/forneycorp.com\/wp-content\/uploads\/2014\/02\/Panel-Mount.jpg\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/02\/Panel-Mount.jpg 512w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/02\/Panel-Mount-300x232.jpg 300w\" alt=\"Panel-Mount\" width=\"512\" height=\"397\" \/><br \/>\nThe PM IDD 9000 is available as single or dual channel. The dual channel has a separate, identical PCB motherboard for each channel. Each board contains six connectors on the side panels. Dual channel shown, bottom board is removed on single channel configuration.<\/p>\n<h4>Panel Mount IDD 9000<\/h4>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-474\" src=\"http:\/\/forneycorp.com\/wp-content\/uploads\/2014\/02\/Rack-Mount.jpg\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/02\/Rack-Mount.jpg 512w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/02\/Rack-Mount-300x232.jpg 300w\" alt=\"Rack-Mount\" width=\"512\" height=\"397\" \/><br \/>\nThe RM IDD 9000 is a dual channel amplifier with a separate identical CPU Processor for each channel. The right side is for Channel 1 and the left side is Channel 2. The RM IDD 9000 is designed for installation into an amplifier rack (Part # 404325-02) in an equipment cabinet.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Featured &amp; Benefits&#8221; tab_id=&#8221;1535228100664-93557475-11d55426-2a926f74-146015e6-4a3f&#8221;][vc_column_text]<\/p>\n<ul>\n<li>Enhanced Discrimination and Tuning \u2013 Increased IDD frequency response options along with spectrum weighting capability for tuning to unique flame patterns.<\/li>\n<li>Storage for eight operating profiles allows BMS controlled or manual file switching for instantaneous recall of optimized performance for a variety of fuels and burner operating conditions.<\/li>\n<li>Flame signal processing can be IR only or UV only on each channel.<\/li>\n<li>Connecting an IDD and UV-4 flame detector to one dual channel IDD 9000 amplifier allows supervision of a burner\/ igniter pair.<\/li>\n<\/ul>\n<h4>Factory Mutual Approved<\/h4>\n<ul>\n<li>Factory Mutual (FM) approval means safe operation and lower insurance rates<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Resources&#8221; tab_id=&#8221;1535228101519-87562f93-8d975426-2a926f74-146015e6-4a3f&#8221;][vc_column_text]<a href=\"http:\/\/forneycorp.com\/wp-content\/uploads\/2014\/02\/IDD9000rev11-2011_PM_RM.pdf\">IDD 9000 Flame Amplifier<\/a>[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;267,268,269&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Product:\u00a0IDD 9000 Flame Detector Amplifier The IDD 9000 Flame Detector Amplifier provides enhanced discrimination and tuning for NFPA<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":256,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-266","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/266","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/comments?post=266"}],"version-history":[{"count":1,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/266\/revisions"}],"predecessor-version":[{"id":270,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/266\/revisions\/270"}],"up":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/256"}],"wp:attachment":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/media?parent=266"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}