{"id":262,"date":"2018-08-25T21:51:38","date_gmt":"2018-08-25T21:51:38","guid":{"rendered":"http:\/\/powerupgs.com\/site\/?page_id=262"},"modified":"2018-08-25T21:51:51","modified_gmt":"2018-08-25T21:51:51","slug":"idd-ultra-uv-flame-detector","status":"publish","type":"page","link":"https:\/\/powerupgs.com\/site\/forney-corporation\/flame-detector\/idd-ultra-uv-flame-detector\/","title":{"rendered":"IDD-Ultra UV Flame Detector"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;263,264&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h4 class=\"custom-prod-title\">Product:\u00a0IDD-Ultra UV Flame Detector<\/h4>\n<p>Forney\u2019s IDD-Ultra Flame Detector is the ideal UV detector for applications with high-temperature requirements.<\/p>\n<p>Forney\u2019s Intelligent Dynamic Detector (IDD) \u2013 Ultra version is designed to accurately detect and discriminate the radiation produced by the combustion of natural gas or light oil.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs][vc_tta_section title=&#8221;Product Overview&#8221; tab_id=&#8221;1535228058413-12a31845-683a5426-2a926f74-14604c35-38ad&#8221;][vc_column_text]Forney\u2019s Intelligent Dynamic Detector (IDD) \u2013 Ultra version is designed to accurately detect and discriminate the radiation produced by the combustion of natural gas or light oil.<\/p>\n<p>The Intelligent Dynamic Detector Ultra (IDD-Ultra) is used in conjunction with Forney\u2019s IDD 9000 amplifiers. (For legacy amplifier compatibility, contact Forney.) The IDD-Ultra solid state circuitry amplifies a continuously changing voltage signal transmitted from the Silicon Carbide (SiC) sensor when flame is sensed. This signal is sent to the amplifier by way of a four conductor cable. The amplifier processes the signal and provides outputs to the burner management system. For trouble-free operation, the electronics of the detector are potted within the cast steel housing. In addition, the amplifier also initiates a periodic check of the sensor and printed circuit board to verify proper operation of the detector assembly, eliminating the need for a mechanical shutter.<\/p>\n<p>\u2022\u00a0<strong>High Temperature Silicon Carbide Sensor \u2013<\/strong>\u00a0High temperature resistance prevents detector head from overheating on the boiler front. Sensitive to ultra violet light radiation prevalent in natural gas and light oil flames.<\/p>\n<p>\u2022\u00a0<strong>Dynamic Flame Sensing Circuitry<\/strong>\u00a0\u2013 Senses only a dynamic flame signal, discriminates flame from hot refractory and other background conditions.<\/p>\n<p>\u2022\u00a0<strong>Compact, Durable Assembly<\/strong>\u00a0\u2013 The printed circuit board and sensor are potted within a cast steel housing providing a maintenance free product.<\/p>\n<p>\u2022\u00a0<strong>Simplified System Maintenance<\/strong>\u00a0\u2013 Quick disconnect, electrical and mechanical connections are used for easy replacement.<\/p>\n<p>\u2022\u00a0<strong>Fiber Optics \u2013\u00a0<\/strong>Optional fixtures are available for fiber optic applications.<\/p>\n<p>\u2022\u00a0<strong>Factory Mutual Approval<\/strong>\u00a0\u2013 \u00a0Factory Mutual (FM) approval means safe operation and lower insurance rates.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Technical Data&#8221; tab_id=&#8221;1535228058480-927f5ae5-e2315426-2a926f74-14604c35-38ad&#8221;][vc_column_text]Products and Accessories:<br \/>\nIDD-Ultra UV Detector Solid State UV Part #38321-29<br \/>\nSpecifications:<br \/>\nMounting: 1\u201d NPT sight pipe fitting<br \/>\nMaterials: Cast Steel Housing, Potted Electronics<br \/>\nElectrical: Supplied by Amplifier, 50 VDC and 15 VDC<br \/>\nElectrical Connections: MS Bayonet connector supplied with cable, 1\/2\u201d flexible conduit required<br \/>\nTemperature Ratings: 32\u00b0F to 250\u00b0F (0\u00b0C to 121\u00b0C)<br \/>\nIf freezing temperatures are expected at the detector head, Forney recommends heat tracing<br \/>\nthe detector sight tube.<br \/>\nConsult Forney for higher temperature applications.<br \/>\nHumidity: 0-95% relative humidity, non-condensing<br \/>\nShipping Weight: 21 oz (0.6 kg)<br \/>\nApprovals: Factory Mutual (FM)<br \/>\nSensor: Silicon Carbide (SiC)<br \/>\nWavelength: 200-425 nm (310 nm center)[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Drawings&#8221; tab_id=&#8221;1535228099870-cf2e50d8-09be5426-2a926f74-14604c35-38ad&#8221;][vc_column_text]<a class=\"cboxElement\" title=\"IDD-Ultra UV Flame Detector\" href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2015\/09\/IDD-Ultra-Dimensions.jpg\" rel=\"lightbox[1447]\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-1449\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2015\/09\/IDD-Ultra-Dimensions.jpg\" sizes=\"auto, (max-width: 683px) 100vw, 683px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2015\/09\/IDD-Ultra-Dimensions.jpg 683w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2015\/09\/IDD-Ultra-Dimensions-300x174.jpg 300w\" alt=\"IDD-Ultra-Dimensions\" width=\"683\" height=\"397\" \/><\/a>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Featured &amp; Benefits&#8221; tab_id=&#8221;1535228100664-93557475-11d55426-2a926f74-14604c35-38ad&#8221;][vc_column_text]\u2022\u00a0<strong>High Temperature Silicon Carbide Sensor \u2013<\/strong>\u00a0High temperature resistance prevents detector head from overheating on the boiler front. Sensitive to ultra violet light radiation prevalent in natural gas and light oil flames.<\/p>\n<p>\u2022\u00a0<strong>Dynamic Flame Sensing Circuitry<\/strong>\u00a0\u2013 Senses only a dynamic flame signal, discriminates flame from hot refractory and other background conditions.<\/p>\n<p>\u2022\u00a0<strong>Compact, Durable Assembly<\/strong>\u00a0\u2013 The printed circuit board and sensor are potted within a cast steel housing providing a maintenance free product.<\/p>\n<p>\u2022\u00a0<strong>Simplified System Maintenance<\/strong>\u00a0\u2013 Quick disconnect, electrical and mechanical connections are used for easy replacement.<\/p>\n<p>\u2022\u00a0<strong>Fiber Optics \u2013\u00a0<\/strong>Optional fixtures are available for fiber optic applications.<\/p>\n<p>\u2022\u00a0<strong>Factory Mutual Approval<\/strong>\u00a0\u2013 \u00a0Factory Mutual (FM) approval means safe operation and lower insurance rates.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Resources&#8221; tab_id=&#8221;1535228101519-87562f93-8d975426-2a926f74-14604c35-38ad&#8221;][vc_column_text]<a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/02\/IDD-Ultra_rev04-2015_8x10_5.pdf\">IDD-Ultra_rev04-2015<\/a>\u00a0Spec Sheet<br \/>\nPublication Number 404005-30[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;263,264&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Product:\u00a0IDD-Ultra UV Flame Detector Forney\u2019s IDD-Ultra Flame Detector is the ideal UV detector for applications with high-temperature requirements.<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":256,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-262","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/262","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/comments?post=262"}],"version-history":[{"count":1,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/262\/revisions"}],"predecessor-version":[{"id":265,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/262\/revisions\/265"}],"up":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/256"}],"wp:attachment":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/media?parent=262"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}