{"id":258,"date":"2018-08-25T21:47:18","date_gmt":"2018-08-25T21:47:18","guid":{"rendered":"http:\/\/powerupgs.com\/site\/?page_id=258"},"modified":"2018-08-25T21:47:18","modified_gmt":"2018-08-25T21:47:18","slug":"hd-flame-detector","status":"publish","type":"page","link":"https:\/\/powerupgs.com\/site\/forney-corporation\/flame-detector\/hd-flame-detector\/","title":{"rendered":"HD Flame Detector"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;259,260&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h4 class=\"custom-prod-title\">Product:\u00a0HD Flame Detector<\/h4>\n<p>Forney\u2019s HD Flame Detector is the best available flame detector for the Power Generation, Petrochemical and Industrial markets. It provides the highest level of flame discrimination in multi-burner applications with an easy to use interface on a mobile app.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs][vc_tta_section title=&#8221;Product Overview&#8221; tab_id=&#8221;1535228058413-12a31845-683a5426-2a926f74-146088de-703a&#8221;][vc_column_text]The Forney High Definition (HD) Flame Detector integrates both Infrared (IR) and Ultraviolet (UV) optical sensors along with an amplifier and high speed signal processor. The high speed signal processor is able to analyze frequency resolution allowing for precise discrimination between multiple burners and background radiation. HD Detector includes two flame relays, one for signals from each optical sensor. Four different profiles are selectable for maximum flexibility under different operating conditions. 4 to 20mA analog outputs are provided for remote display options.<\/p>\n<p>An industry first mobile app is available in two configurations from the Apple Store and Google Play. The Forney HD Detector app will allow the user to select a specific detector via Bluetooth. The user can then monitor the detector on their mobile device. A live Fast Fourier Transform (FFT) is also displayed. To tune the detector, the password protected, Forney HD Detector Pro app will allow the user to specify pick up and drop outs for flame on and flame off within the two user specified frequency ranges. Any fault codes are clearly shown with Reset capability. A PC based RS485 connection capability is also available.<\/p>\n<p>A single, flexible 12 wire custom cable is available in multiple lengths to make field connects simple. In many cases the existing field cabling can be reused. (Existing cables for Forney D85, UniFlame I, and UniFlame II Detectors can be reused with transition adapters.)[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Technical Data&#8221; tab_id=&#8221;1535228058480-927f5ae5-e2315426-2a926f74-146088de-703a&#8221;][vc_column_text]<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td width=\"50%\"><strong>Environmental<\/strong><\/td>\n<td width=\"50%\"><\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Ambient Operating Temperature<\/td>\n<td width=\"50%\">-30\u00b0C to 65\u00b0 C (-22\u00b0 F to 149\u00b0 F)<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Internal Operating Temperature<\/td>\n<td width=\"50%\">Up to 85\u00b0C (185\u00b0 F)<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Ambient Storage and Transportation Temperature<\/td>\n<td width=\"50%\">20\u00b0C to 50\u00b0C (68\u00b0F to 122\u00b0 F)<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Relative Humidity<\/td>\n<td width=\"50%\">40\u00b0C (104\u00b0F), RH 95%<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Vibration Sinusoidal Operating<\/td>\n<td width=\"50%\">Frequency: 5 -200 Hz<br \/>\nAcceleration: 8G<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Flammability Rating<\/td>\n<td width=\"50%\">UL94 HB<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Conformal Coatings<\/td>\n<td width=\"50%\"><\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">RoHS Compliant<\/td>\n<td width=\"50%\"><\/td>\n<\/tr>\n<tr>\n<td width=\"50%\"><strong>Mechanical<\/strong><\/td>\n<td width=\"50%\"><\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Housing Material<\/td>\n<td width=\"50%\">Engineered Polymer<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Weight<\/td>\n<td width=\"50%\">1.2 Kg (2.7 lbs)<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Degree of Protection<\/td>\n<td width=\"50%\">IP65, NEMA 4X<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Sight Tube Mounting<\/td>\n<td width=\"50%\">1\u201d NPT<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Lens Temperature Rating<\/td>\n<td width=\"50%\">538\u00b0C (1000\u00b0 F)<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Purge Air Flow<\/td>\n<td width=\"50%\">Minimum 5 SCFM<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Optical Sensitivity<\/td>\n<td width=\"50%\">Responsive to oil, coal &amp; gas flames using IR &amp; UV spectrum<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Power Supply<\/td>\n<td width=\"50%\">24 VDC ( +10 \/- 15%)<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Steady State Current<\/td>\n<td width=\"50%\">120 ma<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Inrush Current<\/td>\n<td width=\"50%\">350 ma<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Power Consumption<\/td>\n<td width=\"50%\">2.88 watt<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">External In-line Fuse<\/td>\n<td width=\"50%\">1 Amp Fuse Required<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Heat Dissipation<\/td>\n<td width=\"50%\">1.2 Watt<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Flame Relay<\/td>\n<td width=\"50%\">Two (2) independent (fail safe)<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Contacts<\/td>\n<td width=\"50%\">SPST<br \/>\n24 VDC, 1 amp<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Flame Failure Response Time (FFRT)<\/td>\n<td width=\"50%\">1, 2, 3, 4 second (user adjustable)<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Fault Relay<\/td>\n<td width=\"50%\">Internally Wired<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Analog Output<\/td>\n<td width=\"50%\">Sourced 4-20 ma, one for each flame relay<br \/>\nLoad resistance &lt; 500 Ohm<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Digital Inputs<\/td>\n<td width=\"50%\">Two self-powered inputs for up to four file selections<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Communication<\/td>\n<td width=\"50%\">RS-485 \/ Modbus<br \/>\nBluetooth<sup>\u00ae<\/sup><\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Electrical connections<\/td>\n<td width=\"50%\">Standard \u2013 Quick disconnect<br \/>\nATEX version \u2013 Prewired<\/td>\n<\/tr>\n<tr>\n<td width=\"50%\">Prefabricated Cable<\/td>\n<td width=\"50%\">12 Conductor (color coded)<br \/>\nTinned Copper Braid Shield, Black PVC Jacket CSA CMG (UL) PLTC-ER 300V 105C, Fire Resistant \u2013 FT4, UV Resistance<br \/>\nDiameter -0.463\u201d Nominal<br \/>\nWeight \u2013 0.17 lb\/ft<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Drawings&#8221; tab_id=&#8221;1535228099870-cf2e50d8-09be5426-2a926f74-146088de-703a&#8221;][vc_column_text]<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-2083\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2018\/04\/HD-01_Dimensions-1024x416.gif\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2018\/04\/HD-01_Dimensions-1024x416.gif 1024w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2018\/04\/HD-01_Dimensions-300x122.gif 300w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2018\/04\/HD-01_Dimensions-768x312.gif 768w\" alt=\"\" width=\"1024\" height=\"416\" \/>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Featured &amp; Benefits&#8221; tab_id=&#8221;1535228100664-93557475-11d55426-2a926f74-146088de-703a&#8221;][vc_column_text]<\/p>\n<h2><strong>Benefits<\/strong><\/h2>\n<ul>\n<li><em><strong>High Definition<\/strong><\/em>\u00a0\u2013 Maximum discrimination in difficult multi-burner environments.<\/li>\n<li><em><strong>Easy to use<\/strong><\/em>\u00a0\u2013 app available for either smart phones or tablets<\/li>\n<li><em><strong>Installation friendly<\/strong>\u00a0<\/em>\u2013 lightweight housing and single flexible cable<\/li>\n<li><em><strong>Robust<\/strong>\u00a0<\/em>\u2013 2 year warranty in normal operating conditions<\/li>\n<\/ul>\n<h2><strong>Features<\/strong><\/h2>\n<ul>\n<li>Both Infrared (IR) and Ultraviolet (UV) sensors in every unit<\/li>\n<li>High speed microprocessor based signal analysis<\/li>\n<li>Bluetooth\u00ae and RS485 Modbus communications<\/li>\n<li>Simple LED status indicators on HD Detector unit for Power, Flame Relay 1 &amp; 2, Fault, Bluetooth\u00ae, and High Temperature<\/li>\n<li>IP 65 housing and connections<\/li>\n<li>RoHS compliant<\/li>\n<\/ul>\n<p><strong>Worldwide Agency Approvals<\/strong><br \/>\nFM, CE, IECEX, Class I Div 2, Groups B,C &amp;D, ATEX[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Resources&#8221; tab_id=&#8221;1535228101519-87562f93-8d975426-2a926f74-146088de-703a&#8221;][vc_column_text]<a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2017\/07\/HD_Spec_Sheet_rev4-2018.pdf\">HD Flame Detector Spec Sheet<br \/>\n<\/a>Publication Number 404005-32<\/p>\n<p><a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2018\/05\/HD_Manual_372001-17revA-.pdf\">HD Flame Detector Manual<\/a><br \/>\nPublication Number 372001-17<\/p>\n<p><a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2018\/07\/HD_App_Manual_372001-21revA.pdf\">HD Mobile App Manual<\/a><br \/>\nPublication Number 372001-21<\/p>\n<p><a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2018\/07\/HD_Connect_Manual_372001-22revA.pdf\">HD Connect Manual (Windows Software)<\/a><br \/>\nPublication Number 372001-22[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;259,260&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Product:\u00a0HD Flame Detector Forney\u2019s HD Flame Detector is the best available flame detector for the Power Generation, Petrochemical<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":256,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-258","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/comments?post=258"}],"version-history":[{"count":1,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/258\/revisions"}],"predecessor-version":[{"id":261,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/258\/revisions\/261"}],"up":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/256"}],"wp:attachment":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/media?parent=258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}