{"id":237,"date":"2018-08-25T21:36:10","date_gmt":"2018-08-25T21:36:10","guid":{"rendered":"http:\/\/powerupgs.com\/site\/?page_id=237"},"modified":"2018-08-25T21:36:10","modified_gmt":"2018-08-25T21:36:10","slug":"flexible-single-tube","status":"publish","type":"page","link":"https:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/flexible-single-tube\/","title":{"rendered":"Flexible Single Tube"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;239,238&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h4 class=\"custom-prod-title\">Product:\u00a0Flexible Single Tube<\/h4>\n<p>This Class I igniter is located in a tilting tangentially fired boiler adjacent to the main fuel nozzle.<\/p>\n<p>As an oil igniter, the unique rear atomizer results in a single tube extending to the one piece tip. This design eliminates the need for atomizer maintenance.<\/p>\n<p>As a gas igniter, the gas is directed to the tip through the single flexible tube. Stabilization is maintained by a 7.5 inch swirler which creates a low pressure zone just down stream of the nozzle. Combustion air is provided from the windbox.<\/p>\n<p>Forney\u2019s Flexible Single Tube (FST) Igniter provides multi-fuel, stable and reliable ignition for tangential burners utilizing a flexible design for optimal ignition with tilting nozzles.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs][vc_tta_section title=&#8221;Product Overview&#8221; tab_id=&#8221;1535228058413-12a31845-683a5426-2a926f74-14602c81-0904&#8243;][vc_column_text]The Flexible Single Tube (FST) Igniter is a reliable source of ignition energy for use in a tilting tangential type boiler. It is a Class 1, continuous duty, igniter capable of burner ignition and low load support. It is easily installed in the auxiliary air nozzles between the main fuel elevations and is designed with flexible components to accommodate the tilting of the fuel nozzles. The FST Igniter is capable of burning liquid or gaseous fuels. With capacities up to 10% of boiler heat input, the FST improves boiler \/ turbine startup flexibility.<\/p>\n<p>Each FST Igniter includes a flexible fuel gun, a flexible retractable High Energy Spark Igniter (HESI) and a flame detector with a flexible fiber optic assembly. The fuel gun has an air swirler at the furnace end which mixes the windbox air and fuel at the tip to create a stable flame. All major components are fixed to a burner front plate that is designed to match the existing bolt pattern at the burner front. All components are designed to freely tilt with the fuel nozzle through a \u00b130\u00b0 angle. Flame detection is accomplished by the use of either an ultraviolet or infrared detector, depending on the fuel fired.<\/p>\n<p>Optional equipment includes gun retraction, quick disconnect fuel and atomizing air couplings, as well as an electrical junction box.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Technical Data&#8221; tab_id=&#8221;1535228058480-927f5ae5-e2315426-2a926f74-14602c81-0904&#8243;][vc_column_text]<\/p>\n<h4>Specifications<\/h4>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\" width=\"21%\">Fuel:<\/td>\n<td align=\"left\" valign=\"top\" width=\"79%\">No. 2 Oil or Natural Gas<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">BTU Rating:<\/td>\n<td align=\"left\" valign=\"top\">Oil: 10 \u2013 37 MBTU\/hr<br \/>\nGas: 10 \u2013 20 MBTU\/hr<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Fuel Pressure:<\/td>\n<td align=\"left\" valign=\"top\">Oil: 60 \u2013 125 psig<br \/>\nGas: 12 \u2013 25 psig<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Cooling\/Combustion Air:<\/td>\n<td align=\"left\" valign=\"top\">Flow: 40 SCFM<br \/>\nPressure: 6 WC<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Guide Tube OD:<\/td>\n<td align=\"left\" valign=\"top\">2.38\u201d<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Mount Tube OD:<\/td>\n<td align=\"left\" valign=\"top\">2.88\u201d<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Length:<\/td>\n<td align=\"left\" valign=\"top\">As Required, up to 8.5\u2019<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Atomizing Pressure:<\/td>\n<td align=\"left\" valign=\"top\">20 psig (Differential over oil pressure)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Material of Construction:<\/td>\n<td align=\"left\" valign=\"top\">Guide Tube and Mount Tube, Carbon Steel;<br \/>\nGuide Tube Tip and Pilot Area, 304 SST<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Retract Cylinder Air Pressure:<br \/>\n(HESI\/oil gun)<\/td>\n<td align=\"left\" valign=\"top\">60 to 100 psig<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>HESI Specifications<\/h4>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"left\" valign=\"top\" width=\"21%\">Input Voltage:<\/td>\n<td align=\"left\" valign=\"top\" width=\"79%\">120 to 240 VAC, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Input Power:<\/td>\n<td align=\"left\" valign=\"top\">120 VAC @ 1.5 A (2-A fuse); 240 VAC @ 0.75A (1-A fuse)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Output Voltage:<\/td>\n<td align=\"left\" valign=\"top\">2000 VDC<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Output Energy:<\/td>\n<td align=\"left\" valign=\"top\">12 joules per spark<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Spark Rate:<\/td>\n<td align=\"left\" valign=\"top\">3 per second (approximately)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\" valign=\"top\">Duty Cycle:<\/td>\n<td align=\"left\" valign=\"top\">50% at temp 0\u00b0F to 135\u00b0F (-18\u00b0C to 57\u00b0C) Ambient<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Drawings&#8221; tab_id=&#8221;1535228099870-cf2e50d8-09be5426-2a926f74-14602c81-0904&#8243;][vc_column_text]<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-529\" src=\"http:\/\/forneycorp.com\/wp-content\/uploads\/2014\/01\/fst-drawing.jpg\" sizes=\"auto, (max-width: 699px) 100vw, 699px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/fst-drawing.jpg 699w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/fst-drawing-300x132.jpg 300w\" alt=\"fst-drawing\" width=\"699\" height=\"308\" \/>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Featured &amp; Benefits&#8221; tab_id=&#8221;1535228100664-93557475-11d55426-2a926f74-14602c81-0904&#8243;][vc_column_text]<\/p>\n<ul>\n<li><strong>Class 1 Igniter<\/strong><br \/>\nCapacities up to 37 MBTU\/hr which will support ignition under all credible burner light-off or operating conditions.<\/li>\n<li><strong>One Fst Igniter supports twO Fuel Nozzles<\/strong><br \/>\nThis arrangement results in half the number of igniters normally required.<\/li>\n<li><strong>Flame stability<\/strong><br \/>\nThe stainless steel 7 1\/2\u201d air swirler creates a low pressure zone at the tip for stable flame operation.<\/li>\n<li><strong>Low Opacity<\/strong><br \/>\nThe turbulent mixing of the fuel and combustion air caused by the swirler ensures low opacity during cold light-off.<\/li>\n<li><strong>easy retroFit<\/strong><br \/>\nCan be installed between most fuel elevations with minimal or no burner<br \/>\nmodification.<\/li>\n<li><strong>Reliable Ignition<\/strong><br \/>\nCan be installed between most fuel elevations with minimal or no burner<br \/>\nmodification.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Resources&#8221; tab_id=&#8221;1535228101519-87562f93-8d975426-2a926f74-14602c81-0904&#8243;][vc_column_text]<a href=\"http:\/\/forneycorp.com\/wp-content\/uploads\/2014\/01\/FST_rev01-20111.pdf\">FST Igniter Technical Bulletin<\/a><br \/>\nPublication Number 404006-05[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;239,238&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Product:\u00a0Flexible Single Tube This Class I igniter is located in a tilting tangentially fired boiler adjacent to the<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":223,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-237","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/comments?post=237"}],"version-history":[{"count":1,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/237\/revisions"}],"predecessor-version":[{"id":240,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/237\/revisions\/240"}],"up":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/223"}],"wp:attachment":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/media?parent=237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}