{"id":232,"date":"2018-08-25T21:31:27","date_gmt":"2018-08-25T21:31:27","guid":{"rendered":"http:\/\/powerupgs.com\/site\/?page_id=232"},"modified":"2018-08-25T21:31:45","modified_gmt":"2018-08-25T21:31:45","slug":"maxfire-gas-igniter","status":"publish","type":"page","link":"https:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/maxfire-gas-igniter\/","title":{"rendered":"MaxFire\u00ae Gas Igniter"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;233,234&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h4 class=\"custom-prod-title\">Product:\u00a0MaxFire\u00ae Gas Igniter<\/h4>\n<p>The MAXFire\u00ae 100 Series gas igniter incorporates the \u201cprotected primary combustion zone\u201d design in each of the 5 capacities available. The ignition process starts inside the guide tube away from the burner environment resulting in an extremely stable and reliable igniter. Capacities (nominal) range from 1 mmBtu\/hr to 50 mmBtu\/hr.<\/p>\n<p>MAXFire\u00ae gas igniters provide the most reliable source of energy for main flame ignition, flame stabilization, and boiler warm-up.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs][vc_tta_section title=&#8221;Product Overview&#8221; tab_id=&#8221;1535228058413-12a31845-683a5426-2a926f74-14606e20-5036&#8243;][vc_column_text]The MAXFire\u00ae Series 100 gas igniters can be used as a Class 1, Class 2, or Class 3 igniter, depending on burner capacity. The MAXFire\u00ae igniter is easily installed as a retrofit into most burner types based on its size, capacity, and reliable operation.<\/p>\n<p>MAXFire\u00ae gas igniters consist of four major components: a guide tube, a gas transport tube, a spark rod, and a stainless steel diffuser for pilot stabilization. The guide tube houses the spark rod and the gas transport tube, which are easily removed from the guide tube for maintenance purposes by releasing a \u201cV\u201d band retainer, requiring no tools. Cooling\/combustion airflow is directed down the guide tube to support and maintain the primary combustion zone during operation. The controlled mixture of fuel and air in the primary combustion zone results in a highly reliable, stable igniter flame. While out of service, airflow cools the igniter and prevents debris from migrating into the end of the guide tube.<\/p>\n<p>MAXFire\u00ae gas igniters come standard with Forney\u2019s High Energy Spark Igniter (HESI) as the spark source. The HESI produces a powerful 12-joule spark approximately three times per second at the primary combustion zone. The HESI spark tip is a nonfouling, surface-gap tip which is replaceable as a unit by a threaded connection. Optional equipment for the MAXFire\u00ae includes a High Tension Spark (HTSI) source in place of the HESI, mounting hardware, hoses, flame rod and an integral or externally mounted optical flame detector.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Technical Data&#8221; tab_id=&#8221;1535228058480-927f5ae5-e2315426-2a926f74-14606e20-5036&#8243;][vc_column_text]<\/p>\n<h4>Specifications<\/h4>\n<p>Fuel: Natural gas or propane<br \/>\nMinimum Length: 14 inches<br \/>\nGuide Tube Material: 10 &amp; 30 \u2013 Stainless steel<br \/>\n35, 40 &amp; 50 \u2013 Carbon steel with 12\u201d stainless steel at furnace end<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td align=\"center\" valign=\"top\" width=\"12%\">MAXFire<br \/>\nModel<\/td>\n<td align=\"center\" valign=\"top\" width=\"11%\">Capacity<br \/>\nMBtu\/hr<\/td>\n<td align=\"center\" valign=\"top\" width=\"11%\">Guide<br \/>\nTube OD<\/td>\n<td colspan=\"2\" align=\"center\" valign=\"top\">\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" align=\"center\" valign=\"top\">Connections (NPT)<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"top\" width=\"51%\">Gas<\/td>\n<td align=\"center\" valign=\"top\" width=\"49%\">Air<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<td align=\"center\" valign=\"top\" width=\"16%\">Cooling Air<br \/>\nRequirement*<\/td>\n<td align=\"center\" valign=\"top\" width=\"10%\">Nozzle<br \/>\nType<\/td>\n<td align=\"center\" valign=\"top\" width=\"17%\">Typical Fuel<br \/>\nPressure (psig)<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"top\">110<\/td>\n<td align=\"center\" valign=\"top\">0.3 to 1.5<\/td>\n<td align=\"center\" valign=\"top\">1 7\/8\u201d<\/td>\n<td align=\"center\" valign=\"top\" width=\"12%\">1\/2\u201d<\/td>\n<td align=\"center\" valign=\"top\" width=\"11%\">3\/4\u201d<\/td>\n<td align=\"center\" valign=\"top\">23 @ 3<\/td>\n<td align=\"center\" valign=\"top\">Straight<\/td>\n<td align=\"center\" valign=\"top\">5-12<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"top\">130<\/td>\n<td align=\"center\" valign=\"top\">1.5 to 6.0<\/td>\n<td align=\"center\" valign=\"top\">2 7\/8\u201d<\/td>\n<td align=\"center\" valign=\"top\">3\/4\u201d<\/td>\n<td align=\"center\" valign=\"top\">3\/4\u201d<\/td>\n<td align=\"center\" valign=\"top\">45 @ 3<\/td>\n<td align=\"center\" valign=\"top\">Straight or wide<\/td>\n<td align=\"center\" valign=\"top\">5-12<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"top\">135<\/td>\n<td align=\"center\" valign=\"top\">5.0 to 15<\/td>\n<td align=\"center\" valign=\"top\">3 1\/2\u201d<\/td>\n<td align=\"center\" valign=\"top\">1 1\/2\u201d<\/td>\n<td align=\"center\" valign=\"top\">1 1\/2\u201d<\/td>\n<td align=\"center\" valign=\"top\">50 @ 6<\/td>\n<td align=\"center\" valign=\"top\">Straight or wide<\/td>\n<td align=\"center\" valign=\"top\">5-25<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"top\">140<\/td>\n<td align=\"center\" valign=\"top\">5.0 to 25<\/td>\n<td align=\"center\" valign=\"top\">4\u201d<\/td>\n<td align=\"center\" valign=\"top\">1 1\/2\u201d<\/td>\n<td align=\"center\" valign=\"top\">1 1\/2\u201d<\/td>\n<td align=\"center\" valign=\"top\">80 @ 6<\/td>\n<td align=\"center\" valign=\"top\">Straight or wide<\/td>\n<td align=\"center\" valign=\"top\">5-25<\/td>\n<\/tr>\n<tr>\n<td align=\"center\" valign=\"top\">150<\/td>\n<td align=\"center\" valign=\"top\">10 to 50<\/td>\n<td align=\"center\" valign=\"top\">5\u201d<\/td>\n<td align=\"center\" valign=\"top\">TBD<\/td>\n<td align=\"center\" valign=\"top\">TBD<\/td>\n<td align=\"center\" valign=\"top\">120 @ 6<\/td>\n<td align=\"center\" valign=\"top\">Straight or wide<\/td>\n<td align=\"center\" valign=\"top\">5-25<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>*scfm@inches w.c. above windbox<\/p>\n<h4>HESI Specifications<\/h4>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td width=\"21%\">Input Voltage:<\/td>\n<td width=\"79%\">120 to 240 VAC, 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Input Power:<\/td>\n<td>120 VAC @ 1.5 A (2-A fuse); 240 VAC @ 0.75A (1-A fuse)<\/td>\n<\/tr>\n<tr>\n<td>Output Voltage:<\/td>\n<td>2000 VDC<\/td>\n<\/tr>\n<tr>\n<td>Output Energy:<\/td>\n<td>12 joules per spark<\/td>\n<\/tr>\n<tr>\n<td>Spark Rate:<\/td>\n<td>3 per second (approximately)<\/td>\n<\/tr>\n<tr>\n<td>Duty Cycle:<\/td>\n<td>50% at temp 0\u00b0F to 135\u00b0F (-18\u00b0C to 57\u00b0C) Ambient<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>HTSI Specifications<\/h4>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td width=\"21%\">Amperage:<\/td>\n<td width=\"79%\">20 mA<\/td>\n<\/tr>\n<tr>\n<td>Input Voltage:<\/td>\n<td>120 to 240 VAC 50\/60 HZ<\/td>\n<\/tr>\n<tr>\n<td>Output Voltage:<\/td>\n<td>6000 VAC<\/td>\n<\/tr>\n<tr>\n<td>Duty Cycle:<\/td>\n<td>100% at temperature rating<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Drawings&#8221; tab_id=&#8221;1535228099870-cf2e50d8-09be5426-2a926f74-14606e20-5036&#8243;][vc_column_text]<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-526 size-full\" src=\"http:\/\/forneycorp.com\/wp-content\/uploads\/2014\/01\/maxfire-drawing.jpg\" sizes=\"auto, (max-width: 699px) 100vw, 699px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/maxfire-drawing.jpg 699w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/maxfire-drawing-300x132.jpg 300w\" alt=\"maxfire-drawing\" width=\"699\" height=\"308\" \/>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Featured &amp; Benefits&#8221; tab_id=&#8221;1535228100664-93557475-11d55426-2a926f74-14606e20-5036&#8243;][vc_column_text]<\/p>\n<ul>\n<li><strong>Class 1, 2 or 3 Gas Igniter<\/strong><br \/>\nCapacity range from 0.3 to 50 MBtu\/hr.<\/li>\n<li><strong>Application Flexibility\u00a0<\/strong><br \/>\nThe protected primary combustion zone ensures reliable operation in multiple<br \/>\nenvironments.<\/li>\n<li><strong>Reliable Ignition<\/strong><br \/>\n99% ignition rate in most applications<\/li>\n<li><strong>Cooling \/ Combustion air<\/strong><br \/>\nLow cooling\/combustion air requirements.<\/li>\n<li><strong>Low Maintenance requirements<\/strong><br \/>\nNo moving parts, a self-cleaning spark tip and no tools required to perform periodic inspection<\/li>\n<li><strong>Durability<\/strong><br \/>\nHeavy duty material and no moving parts to wear out.<\/li>\n<li><strong>Compatibility<\/strong><br \/>\nFits most existing mount tubes minimizing retrofit installation costs.<\/li>\n<li><strong>Spark Source Options<\/strong><br \/>\nThe nonfouling HESI comes standard. HTSI provides high performance at an economical price.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Resources&#8221; tab_id=&#8221;1535228101519-87562f93-8d975426-2a926f74-14606e20-5036&#8243;][vc_column_text]<a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/02\/MaxFire100_rev04-2015_8x10_5.pdf\">MAXFire 100 Series Igniter Technical Bulletin<br \/>\nPublication 404006-19<\/a>[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;233,234&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Product:\u00a0MaxFire\u00ae Gas Igniter The MAXFire\u00ae 100 Series gas igniter incorporates the \u201cprotected primary combustion zone\u201d design in each<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":223,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-232","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/232","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/comments?post=232"}],"version-history":[{"count":1,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/232\/revisions"}],"predecessor-version":[{"id":235,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/232\/revisions\/235"}],"up":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/223"}],"wp:attachment":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/media?parent=232"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}