{"id":223,"date":"2018-08-25T21:11:54","date_gmt":"2018-08-25T21:11:54","guid":{"rendered":"http:\/\/powerupgs.com\/site\/?page_id=223"},"modified":"2018-08-26T05:20:07","modified_gmt":"2018-08-26T05:20:07","slug":"igniters","status":"publish","type":"page","link":"https:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/","title":{"rendered":"Igniters"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]Igniters provide the ignition energy to ignite the main fuel for utility and large industrial steam generators. Forney provides a complete line of oil and natural gas igniters for all burner types.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]<\/p>\n<div class=\"pc-feat-img\"><img loading=\"lazy\" decoding=\"async\" class=\"attachment-full wp-post-image\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/DURAFire-copy.jpg\" alt=\"\" width=\"200\" height=\"141\" \/><\/div>\n<p>&nbsp;<\/p>\n<div class=\"pc-text\">\n<h4><a href=\"http:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/durafire-oil-igniter\/\">Oil Igniter DURAFire\u00ae<\/a><\/h4>\n<p>The DURAFire\u00ae air atomized No. 2 oil igniter features the only \u201cprotected primary combustion zone\u201d design on the market. As a result this igniter is self-stabilized, highly reliable and requires virtu \u2026<\/p>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]<\/p>\n<div class=\"pc-feat-img\"><img loading=\"lazy\" decoding=\"async\" class=\"attachment-full wp-post-image\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/Maxfire-8_575.jpg\" alt=\"MaxFire Gas Igniter\" width=\"200\" height=\"139\" \/><\/div>\n<p>&nbsp;<\/p>\n<div class=\"pc-text\">\n<h4><a href=\"http:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/maxfire-gas-igniter\/\">MaxFire\u00ae Gas Igniter<\/a><\/h4>\n<p>The MAXFire\u00ae 100 Series gas igniter incorporates the \u201cprotected primary combustion zone\u201d design in each of the 5 capacities available. The ignition process starts inside the guide tube away from the b \u2026<\/p>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]<\/p>\n<div class=\"pc-feat-img\"><img loading=\"lazy\" decoding=\"async\" class=\"attachment-full wp-post-image\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/fst-featured-img.jpg\" alt=\"\" width=\"199\" height=\"115\" \/><\/div>\n<p>&nbsp;<\/p>\n<div class=\"pc-text\">\n<h4><a href=\"http:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/flexible-single-tube\/\">Flexible Single Tube<\/a><\/h4>\n<p>This Class I igniter is located in a tilting tangentially fired boiler adjacent to the main fuel nozzle. As an oil igniter, the unique rear atomizer results in a single tube extending to the one piece \u2026<\/p>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/3&#8243;][vc_column_text]<\/p>\n<div class=\"pc-feat-img\"><img loading=\"lazy\" decoding=\"async\" class=\"attachment-full wp-post-image\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/q87-featured-img.jpg\" alt=\"\" width=\"201\" height=\"116\" \/><\/div>\n<p>&nbsp;<\/p>\n<div class=\"pc-text\">\n<h4><a href=\"http:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/q87-igniter\/\">Q87 Igniter<\/a><\/h4>\n<p>The Q87 igniter is the best choice when dual fuel (natural gas and No. 2 oil) is required. With a change-out of the internals, the Q87 can switch from firing one fuel to another. It is also the choice \u2026<\/p>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]<\/p>\n<div class=\"pc-feat-img\"><img loading=\"lazy\" decoding=\"async\" class=\"attachment-full wp-post-image\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/horn-rev-feature-img.jpg\" alt=\"\" width=\"201\" height=\"116\" \/><\/div>\n<p>&nbsp;<\/p>\n<div class=\"pc-text\">\n<h4><a href=\"http:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/horn-igniter\/\">Horn Igniter<\/a><\/h4>\n<p>The Forney horn igniter is designed to be a direct replacement for the OEM igniter on tangentially fired boilers. This igniter features improvements such as the high energy spark igniter (HESI), optic \u2026<\/p>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_column_text]<\/p>\n<div class=\"pc-feat-img\"><img loading=\"lazy\" decoding=\"async\" class=\"attachment-full wp-post-image\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/01\/HESI_IgniterAssembly.jpg\" alt=\"\" width=\"201\" height=\"115\" \/><\/div>\n<p>&nbsp;<\/p>\n<div class=\"pc-text\">\n<h4><a href=\"http:\/\/powerupgs.com\/site\/forney-corporation\/igniters\/hesi-igniter\/\">HESI Igniter<\/a><\/h4>\n<p>The HESI is a Class 3 Igniter used for direct spark ignition of oil or gas igniters, small burners, and combustion turbines. The Standard HESI is FM approved and the CE Version meets the Low Voltage D \u2026<\/p>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text]Igniters provide the ignition energy to ignite the main fuel for utility and large industrial steam generators. Forney provides a complete line of oil and natural<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":129,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-223","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/223","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/comments?post=223"}],"version-history":[{"count":5,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/223\/revisions"}],"predecessor-version":[{"id":317,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/223\/revisions\/317"}],"up":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/129"}],"wp:attachment":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/media?parent=223"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}