{"id":217,"date":"2018-08-25T21:07:00","date_gmt":"2018-08-25T21:07:00","guid":{"rendered":"http:\/\/powerupgs.com\/site\/?page_id=217"},"modified":"2018-08-25T21:07:16","modified_gmt":"2018-08-25T21:07:16","slug":"standard-duct-burner","status":"publish","type":"page","link":"https:\/\/powerupgs.com\/site\/forney-corporation\/burners\/duct-burners\/standard-duct-burner\/","title":{"rendered":"Standard Duct Burner"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;218,219,220&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]<\/p>\n<h4 class=\"custom-prod-title\">Product:\u00a0Standard Duct Burner<\/h4>\n<p>Easy configuration allows for many different uses that include: limited space applications, Fresh Air firing,and reheating of process air streams and SCR inlet heating.<\/p>\n<p>The standard burner comes complete with investment castings (stainless steel), high energy ignition and strong supports for long life. We also supply integral frames and distribution grids. Contact Forney with your project specifications.<\/p>\n<p>Forney duct burners offer reliable performance and dependability to meet the complex needs of the combined cycle and cogeneration industries.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_tabs][vc_tta_section title=&#8221;Product Overview&#8221; tab_id=&#8221;1535228058413-12a31845-683a5426-2a926f74-1460&#8243;][vc_column_text]<\/p>\n<h4>Applications<\/h4>\n<ul>Forney duct burners are used in various applications including:<\/p>\n<li>Cogeneration and Combined Cycle \u2013 Increase steam generation and plant power output.<\/li>\n<li>Fresh Air Firing \u2013 Used as a backup source of hot gas to HRSG\/WHRU when combustion turbine is off-line.<\/li>\n<li>Air Heaters \u2013 Heat a large volume of air with minimal pressure drop.<\/li>\n<li>Process Heating \u2013 Many different process streams can be heated, including but not limited to SCR Reheat<br \/>\napplications, Ammonia\/Urea Vaporizers and CFB inlet air heaters.<\/li>\n<\/ul>\n<h4>Product Overview<\/h4>\n<p>Forney duct burners provide clean combustion for supplemental firing of turbine exhaust gas, fresh air, and other process streams. Forney incorporates solid engineering and structural design with durable materials to deliver superior quality. From high temperature applications to repeatedly cycled units, Forney selects the right design and correct material for varying conditions. Stainless steel construction provides long equipment life for components in the exhaust gas stream, including stabilizers, fuel manifolds, baffles and igniters.<\/p>\n<p>Forney\u2019s duct burner firing history dates back to the 1960\u2019s and has expanded to the variety of duct burner designs offered today. These include the adVantage\u00ae, Modified adVantage\u00ae, Conventional, and Compact duct burner designs. Each design is unique to the conditions and environment presented. Forney engineers select the appropriate design given the spacing and design constraints. The adVantage\u00ae and modified adVantage\u00ae duct burner are used in applications with high water content when emissions are a concern. The Conventional and Compact duct burner designs provide flexible solutions for smaller duct sizes.<\/p>\n<p>Forney offers a versatile line of duct burner solutions to meet the ever changing demands for today\u2019s power and industrial markets. Forney\u2019s range of duct burner designs allow users to accommodate for every environment. Forney duct burners can be found in all markets from large cogeneration plants and refineries to hotels and colleges.<\/p>\n<p>The proven experience, flexible designs, and durable construction make Forney the best investment in duct burners.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Technical Data&#8221; tab_id=&#8221;1535228058480-927f5ae5-e2315426-2a926f74-1460&#8243;][vc_column_text]<\/p>\n<h4>Scope of Supply<\/h4>\n<p>Forney supplies a complete scope of equipment with our duct burner system.<\/p>\n<ul>Typical Scope:<\/p>\n<li>Horizontal Burner Elements, Integral Flow Baffles and Supports<\/li>\n<li>ANSI B31.1 Fuel Skid<\/li>\n<li>Burner Management System<\/li>\n<li>Scanner Cooling Air Blowers<\/li>\n<li>MAXFire\u00ae Igniter with HESI<\/li>\n<li>Flame Scanner<\/li>\n<\/ul>\n<ul>Optional Scope:<\/p>\n<li>Distribution Grid and Burner Frame (for ease of installation)<\/li>\n<li>Inlet Fuel Pressure Reduction<\/li>\n<li>CFD<\/li>\n<li>Fuel Flow Measurement<\/li>\n<li>Augmenting Air System<\/li>\n<li>Interconnecting Piping<\/li>\n<li>ANSI B31.3 Fuel Skid<\/li>\n<\/ul>\n<h4>Operating Conditions<\/h4>\n<p>Forney duct burners offer customized solutions with flexible operating conditions.<br \/>\n<strong>Heat Input:<\/strong>\u00a010 \u2013 1,100 MMBtu\/hr, LHV<br \/>\n<strong>Inlet Exhaust Gas Flow:<\/strong>\u00a030,000 \u2013 5,750,000 lbs\/hr<br \/>\n<strong>Inlet Exhaust Gas Temperature:<\/strong>\u00a0up to 1,250\u00b0F<\/p>\n<p>Depending on specific emission requirements, augmenting air may be required when inlet oxygen levels and\/or turbine exhaust gas (TEG) temperatures are very low. Even temperature distribution is key to system performance and is highly influenced by the uniformity of the combustion air \/ TEG velocity profile. Typical exhaust gas distribution to the duct burner should be a minimum of \u00b120% of the average velocity over 90% of the duct cross section.[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Drawings&#8221; tab_id=&#8221;1535228099870-cf2e50d8-09be5426-2a926f74-1460&#8243;][vc_column_text]Forney Duct Burner Stabilizer Options<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-487\" src=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2013\/12\/standardDB-drawing.jpg\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" srcset=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2013\/12\/standardDB-drawing.jpg 512w, http:\/\/www.forneycorp.com\/wp-content\/uploads\/2013\/12\/standardDB-drawing-300x232.jpg 300w\" alt=\"standardDB-drawing\" width=\"512\" height=\"397\" \/>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Featured &amp; Benefits&#8221; tab_id=&#8221;1535228100664-93557475-11d55426-2a926f74-1460&#8243;][vc_column_text]<\/p>\n<h4>Features &amp; Benefits<\/h4>\n<ul>\n<li><strong>Durable Flame Stabilizers<\/strong><br \/>\nInvestment cast stabilizer design utilizes the cooling effects of the exhaust gas stream to ensure long life and consistent performance.<\/li>\n<li><strong>Reliable light-off<\/strong><br \/>\nHigh Energy Spark Ignition (HESI) is provided as standard equipment for consistent performance in low oxygen and high water<br \/>\nvapor environments.<\/li>\n<li><strong>Flow Baffles<\/strong><br \/>\nForney includes baffles when needed for improved mixing of gases and shortened flame lengths.<\/li>\n<li><strong>Augmenting Air<\/strong><br \/>\nAugmenting air is added in unique cases where firing conditions require supplemental oxygen and\/or low exhaust gas temperature adversely affect combustion performance.<\/li>\n<li><strong>Integral Support<\/strong><br \/>\nSupports are included when needed for the duct burner elements to reduce vibration caused by vortex shedding.<\/li>\n<li><strong>Low NOx and Low CO<\/strong><br \/>\nForney emissions meet or exceed those required in today\u2019s strict regulatory environment.<\/li>\n<li><strong>Detailed engineering<\/strong><br \/>\nA dedicated engineering team ensures the proper design for each project.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Resources&#8221; tab_id=&#8221;1535228101519-87562f93-8d975426-2a926f74-1460&#8243;][vc_column_text]<a href=\"http:\/\/www.forneycorp.com\/wp-content\/uploads\/2014\/02\/Duct_Burners.pdf\">Duct Burner Technical Bulletin<\/a><br \/>\nPublication Number 404004-06[\/vc_column_text][\/vc_tta_section][\/vc_tta_tabs][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row equal_height=&#8221;yes&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_gallery type=&#8221;flexslider_slide&#8221; interval=&#8221;3&#8243; images=&#8221;218,219,220&#8243; img_size=&#8221;420&#215;290&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text] Product:\u00a0Standard Duct Burner Easy configuration allows for many different uses that include: limited space applications, Fresh Air firing,and<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":199,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-217","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/comments?post=217"}],"version-history":[{"count":1,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/217\/revisions"}],"predecessor-version":[{"id":221,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/217\/revisions\/221"}],"up":[{"embeddable":true,"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/pages\/199"}],"wp:attachment":[{"href":"https:\/\/powerupgs.com\/site\/wp-json\/wp\/v2\/media?parent=217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}